Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Acta Cardiol Sin ; 39(3): 449-456, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-37229330

RESUMEN

Background: The superiority of the new-generation self-expanding Evolut R compared with the first-generation CoreValve with regards to outcomes after transcatheter aortic valve replacement (TAVR) is unclear. The aim of this study was to investigate the hemodynamic and clinical performance of Evolut R compared with its direct predecessor, CoreValve, in a Taiwanese population. Methods: This study included all consecutive patients who underwent TAVR with either CoreValve or Evolut R between March 2013 and December 2020. Thirty-day Valve Academic Research Consortium-2 (VARC-2)-defined outcomes and hemodynamic performances were investigated. Results: There were no significant differences in baseline demographic characteristics between the patients receiving CoreValve (n = 117) or Evolut R (n = 117). Aortic valve-in-valve procedures for failed surgical bioprosthesis and procedures under conscious sedation were performed significantly more often with Evolut R. Pre-dilatation was performed significantly more often and contrast media volume was significantly higher with CoreValve. Stroke (0% vs. 4.3%, p = 0.024) and the need for emergent conversion to open surgery (0% vs. 5.1%, p = 0.012) were significantly lower in Evolut R than in CoreValve recipients. Evolut R significantly reduced 30-day composite safety endpoint (4.3% vs. 15.4%, p = 0.004). Conclusions: Advancements in transcatheter valve technologies have resulted in improved outcomes for patients undergoing TAVR with self-expanding valves. With the new-generation Evolut R, device success was high and the 30-day composite safety endpoint was significantly reduced after TAVR compared with CoreValve.

2.
J Colloid Interface Sci ; 643: 373-384, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37080044

RESUMEN

Development of tumor microenvironment (TME) modifying nanomedicine with cooperative effect between multiple stimuli responsive therapeutic modalities is necessary to achieve lower dosage induced tumor specific therapy. Accordingly, herein, a multifunctional MnOx NSs@BSA-IR780-GOx nanocomposite (MBIG NCs) is developed to modulate the oxidative stress in TME, and thus attain higher therapeutic efficacy. In the presence of glucose, the as-synthesized MBIG NCs are served as a chemodynamic agents and generated reactive oxygen species (ROS) by self-activation through a cascade of reactions from glucose oxidase (GOx) and manganese oxide nanosheets (MnOx NSs). Also, the MBIG NCs demonstrated excellent photodynamic properties upon irradiation with 808 nm laser owing to the presence of IR780. The combination of glucose-mediated chemodynamic and light-mediated photodynamic properties generated higher ROS than that obtained with individual stimuli. Further, the MBIG NCs exhibited photothermal effect with conversion efficiency of 33.8 %, which helped to enhance the enzymatic activities. In in vitro studies, the MBIG NCs exhibited good biocompatibility to cancerous and non-cancerous cells under non-stimulus conditions. Nevertheless, in the presence of glucose and light stimuli, they triggered more than 90 % cell toxicity at 200 ppm concentration via the cooperative effect between starvation therapy, chemodynamic therapy, and phototherapy. Furthermore, the MBIG NCs demonstrated magnetic resonance and fluorescence imaging properties. These results are suggesting that MBIG NCs would be potential theranostic agents to for cancer diagnosis and target specific therapy. More importantly, the fabrication process is paving a way to improve the aqueous dispersibility, stability, and bio-applicability of MnOx NSs and IR780.


Asunto(s)
Nanocompuestos , Nanopartículas , Neoplasias , Humanos , Oxígeno Singlete , Especies Reactivas de Oxígeno , Medicina de Precisión , Neoplasias/diagnóstico por imagen , Neoplasias/tratamiento farmacológico , Nanocompuestos/uso terapéutico , Línea Celular Tumoral , Nanopartículas/uso terapéutico , Microambiente Tumoral
3.
J Cardiothorac Surg ; 18(1): 82, 2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36882839

RESUMEN

BACKGROUND: Pump exchange surgery of left ventricular assist device (LVAD) has been demonstrated in several studies; however, information for Asian patients was limited. CASE PRESENTATION: A 63-year-old man underwent a pump upgrade from HeartMate II to HeartMate 3 for driveline damage through limited left anterior thoracotomy and lower partial sternotomy. He did not experience any hemodynamic adverse events or device malfunction during postoperative follow-ups of 12 months. We also reviewed all published cases with HeartMate II exchange to HeartMate 3. CONCLUSIONS: The case demonstrated that it was safe and feasible to perform HMII LVAD exchange to HM3 through a limited approach for Asian patients.


Asunto(s)
Corazón Auxiliar , Masculino , Humanos , Persona de Mediana Edad , Corazón Auxiliar/efectos adversos , Periodo Posoperatorio , Esternotomía
4.
Ann Thorac Surg ; 114(5): 1612-1619, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-34678284

RESUMEN

BACKGROUND: Little is known about the incidence of prosthesis-patient mismatch (PPM) and its impact after transcatheter aortic valve replacement with self-expanding valves in an Asian population. We aimed to assess postprocedural effective orifice area with standardized methods and the impact of PPM on midterm outcomes after CoreValve or Evolut R (Medtronic) implantation in an Asian population. METHODS: Among 201 consecutive patients undergoing CoreValve or Evolut R implantation, PPM was assessed at 30 days and defined based on core laboratory measured indexed effective orifice area as severe (less than 0.65 cm2/m2) or moderate (0.65 to 0.85 cm2/m2). Multivariable regression models were utilized to examine predictors of PPM as well as mortality and rehospitalization for heart failure at midterm follow-up. RESULTS: Moderate and severe PPM were observed after self-expanding valves in 37 patients (18.4%) and 3 patients (1.5%), respectively. These 40 patients were included in the PPM group. Predictors of PPM included female sex, larger body surface area, and lower left ventricular ejection fraction. At midterm (median 30.4 months; interquartile range, 17 to 57.8) follow-up, patients with PPM had an increased risk of all-cause death (adjusted hazard ratio 1.95; 95% confidence interval, 1.08 to 3.53; P = .027), cardiovascular mortality (adjusted hazard ratio 3.38; 95% confidence interval, 1.04 to 10.99; P = .043), and rehospitalization for heart failure (adjusted hazard ratio 2.40; 95% confidence interval, 1.11 to 5.17; P = .025). CONCLUSIONS: Patient-prosthesis mismatch was associated with higher midterm mortality and rehospitalization for heart failure in an Asian population. The expected postprocedural effective orifice area for any given valve size may be helpful in preprocedural decision making to avoid PPM.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Prótesis Valvulares Cardíacas/efectos adversos , Válvula Aórtica/cirugía , Volumen Sistólico , Diseño de Prótesis , Resultado del Tratamiento , Función Ventricular Izquierda , Insuficiencia Cardíaca/etiología , Factores de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos
5.
ESC Heart Fail ; 8(4): 3418-3421, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34085412

RESUMEN

A 69-year-old male underwent concomitant left ventricular assist device (LVAD) implantation and aortic valve repair procedure for moderate aortic insufficiency (AI). Due to recurrence of symptomatic heart failure and post-repair AI deterioration from trivial to moderate-to-severe insufficiency 2 months later, transcatheter aortic valve implantation (TAVI) was arranged. During TAVI, intraoperative extracorporeal membrane oxygenation was used to maintain stable haemodynamics and to ensure a safe environment for prosthesis deployment. Postoperative 5 month follow-up revealed no AI and no paravalvular leakage.


Asunto(s)
Insuficiencia de la Válvula Aórtica , Oxigenación por Membrana Extracorpórea , Corazón Auxiliar , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Insuficiencia de la Válvula Aórtica/diagnóstico , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Humanos , Masculino , Resultado del Tratamiento
6.
J Biophotonics ; 13(10): e202000116, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32649064

RESUMEN

Near-infrared spectroscopy (NIRS) has been proposed as a noninvasive modality for detecting complications in patients undergoing extracorporeal membrane oxygenation (ECMO), and it can simultaneously reveal the global circulatory status of these patients. We optimized ECMO therapy on the basis of real-time peripheral NIRS probing. Three patients underwent venoarterial (VA) ECMO and one patient underwent venovenous (VV) ECMO. All patients received peripheral ECMO cannulation with routine distal perfusion catheter placement. We designed an experimental protocol to adjust ECMO blood flow over 1 hour. Hemodynamic responses were measured using NIRS devices attached to the calf at approximately 60% of the distance from the ankle to the knee. HbO2 levels change substantially with adjustments in ECMO flow, and they are more sensitive than HHb levels and the tissue saturation index (TSI) are. NIRS for optimizing ECMO therapy may be reliable for monitoring global circulatory status.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Humanos , Perfusión , Proyectos Piloto , Estudios Retrospectivos , Espectroscopía Infrarroja Corta
7.
Interact Cardiovasc Thorac Surg ; 28(3): 496-498, 2019 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-30312393

RESUMEN

Transcatheter heart valve-in-valve implantation in failed surgical bioprosthetic valves has shown promising outcomes, prompting the stepwise expansion of their applications in different clinical scenarios. Recently, there is increased interest in valve-in-valve techniques for the treatment of patients with complex congenital heart disease. Herein, we report a case of successful transapical transcatheter atrioventricular valve-in-valve implantation in a patient with Fontan circulation and dextrocardia. The patient was previously treated with total cavopulmonary connection and atrioventricular valve replacement with recurrent prosthesis dysfunction.


Asunto(s)
Bioprótesis , Cateterismo Cardíaco/métodos , Dextrocardia/cirugía , Procedimiento de Fontan/métodos , Enfermedades de las Válvulas Cardíacas/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvulas Cardíacas/cirugía , Adulto , Dextrocardia/diagnóstico , Femenino , Enfermedades de las Válvulas Cardíacas/diagnóstico , Humanos , Diseño de Prótesis , Tomografía Computarizada por Rayos X
9.
Eur J Cardiothorac Surg ; 54(5): 853-859, 2018 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-29617931

RESUMEN

OBJECTIVES: Robotic mitral valve replacement (MVR) emerged in the late 1990s as an alternative approach to conventional sternotomy. With the increased use of bioprosthetic valves worldwide and strong patient desire for minimally invasive procedures, the safety and feasibility of robotic MVRs with bioprosthetic valves require investigation. METHODS: Between January 2013 and May 2017, 52 consecutive patients underwent robotic MVRs using the da Vinci Si surgical system (Intuitive Surgical Inc., Sunnyvale, CA, USA). Their mean age was 55.1 ± 13.8 years, and mean EuroSCORE II was 2.25% ± 1.25%. Among the enrolled patients, 32 (61.5%) patients presented with preoperative atrial fibrillation, 6 (11.5%) patients had experienced embolic stroke and 5 (9.6%) patients had undergone previous cardiac surgery. The operations were performed using cardiopulmonary bypass (CPB) under an arrested heart status. RESULTS: Five porcine valves and 47 bovine valves were implanted. A total of 38 (73.1%) patients received concomitant cardiac procedures, including 26 Cox-maze IV procedures, 12 tricuspid valve repairs and 5 atrial septal defect repairs. The mean aortic cross-clamp and CPB times were 141.3 ± 34.3 min and 217.1 ± 42.0 min, respectively. There was no operative mortality. During the mean follow-up of 29 ± 15 months, no prosthesis degeneration was noted. The average left atrial dimension exhibited a significant decrease from 51.4 ± 11.5 mm to 42.6 ± 10.1 mm. CONCLUSIONS: Robotic MVR with bioprosthetic valves is safe, feasible and reproducible. Mid-term results are encouraging. Both aortic cross-clamp and CPB times can be improved with experience.


Asunto(s)
Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas/métodos , Prótesis Valvulares Cardíacas , Válvula Mitral/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Adulto , Anciano , Ecocardiografía , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias , Diseño de Prótesis , Estudios Retrospectivos , Procedimientos Quirúrgicos Robotizados/efectos adversos , Procedimientos Quirúrgicos Robotizados/instrumentación
10.
J Thorac Dis ; 9(12): E1060-E1063, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29312766

RESUMEN

Isolated ostial stenosis (IOS) is a rare disease that encroaches on aorto-coronary junction of uncertain etiology. All distal coronary vessels present normally. IOS occurs predominantly in premenopausal young women with few risk factors for atherosclerotic disease. Here, we report a 40-year-old woman who had experienced crescendo angina for 4 months. Surgical revascularization was achieved by robotic totally endoscopic coronary artery bypass (TECAB) with left internal thoracic artery (LITA) graft. She resumed her daily tasks without difficulties 1 week after the operation. Postoperative computed tomographic angiography disclosed good opacification of the LITA graft and distal runoff. Robotic TECAB is a potentially feasible alternative for IOS patients, particularly in premenopausal young woman, with obvious benefits of cosmetic appearance and speedy recovery.

11.
Ann Thorac Surg ; 103(1): e35-e37, 2017 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-28007269

RESUMEN

Anomalous origin of the right coronary artery (ARCA) from the left Valsalva sinus is a rare but known cause of sudden cardiac death. Surgical revascularization techniques include coronary artery bypass grafting, unroofing, and reimplantation. We report 4 patients who underwent robot-assisted totally endoscopic coronary artery bypass (TECAB) for ARCA as an alternative surgical option. In 3 patients, a single aortocoronary saphenous vein bypass was performed, and in 1 patient the right internal mammary artery was used. All grafts are patent as shown by computed tomographic angiography or cardiac catheterization. We claim that totally endoscopic coronary artery bypass is feasible and safe for anomalous origin of the right coronary artery.


Asunto(s)
Puente de Arteria Coronaria/métodos , Anomalías de los Vasos Coronarios/cirugía , Vasos Coronarios/cirugía , Procedimientos Endovasculares/métodos , Adulto , Angiografía Coronaria/métodos , Anomalías de los Vasos Coronarios/diagnóstico , Vasos Coronarios/diagnóstico por imagen , Femenino , Humanos , Masculino , Tomografía Computarizada por Rayos X
12.
Medicine (Baltimore) ; 96(50): e8949, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29390286

RESUMEN

RATIONALE: Purulent pericarditis is a rare and usually fatal disease. Immunodeficiency state and preexisting pericardial effusion can predispose patients to infections. However, we are not aware of similar cases in patients with adult-onset Still's disease (AOSD). In addition, it is seldom caused by Salmonella bacteria. PATIENT CONCERNS: We report a 30-year-old woman with dyspnea on exertion and epigastric fullness. She was newly diagnosed with AOSD 4 months previously and medicated with prednisolone. DIAGNOSES: Transthoracic echocardiography (TTE) and computed tomography revealed a thickened pericardium with loculations in the pericardial space, consistent with purulent constrictive pericarditis. Subsequent cultures of blood and pericardial fluid yielded S enteritidis. INTERVENTIONS: She underwent subtotal pericardiectomy through a limited median sternotomy, and antibiotic therapy (ceftriaxone) for 1 month. OUTCOMES: The New York Heart Association functional classification downgraded from class III to class I. There was no recurrence during the 1-year follow-up. LESSONS: This case presents an opportunity to highlight the importance of considering purulent pericarditis in patients previously diagnosed with AOSD. High clinical suspicion, early diagnosis, and prompt management can result in a better outcome in purulent pericarditis.


Asunto(s)
Pericarditis Constrictiva/microbiología , Salmonella enteritidis/aislamiento & purificación , Enfermedad de Still del Adulto/complicaciones , Enfermedad de Still del Adulto/diagnóstico , Adulto , Antibacterianos/uso terapéutico , Terapia Combinada , Ecocardiografía , Femenino , Humanos , Pericarditis Constrictiva/diagnóstico por imagen , Pericarditis Constrictiva/terapia , Esternotomía
13.
Mol Med Rep ; 10(3): 1531-6, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25017119

RESUMEN

Bladder cancer is one of the causes of cancer­related death and has a high mortality rate due to its metastatic ability. Naringenin, a bioactive compound predominantly found in citrus fruits, exhibits several cellular functions, including anti­oxidant, ­lipidemia and ­cancer abilities. However, the effects of naringenin on bladder cancer cells are yet to be elucidated. The present study investigated the molecular mechanisms underlying the effects of naringenin on the migration of TSGH­8301 bladder cancer cells. Treatment with naringenin at doses ranging between 0 and 300 µM over a period of 24 h was found to reduce cell viability. Furthermore, zymography and western blot analysis revealed that naringenin reduced the expression of matrix metalloproteinase (MMP)­2 in a dose­dependent manner, and repressed its activity. Naringenin also reduced TSGH­8301 cell migration in a concentration­dependent manner, as evidenced by wound healing and Transwell® assays. In addition, naringenin was found to inhibit AKT activity and block the nuclear translocation of nuclear factor κ­light­chain­enhancer of activated B cells. In conclusion, the findings of the present study show that naringenin is capable of inhibiting bladder cancer cell migration through the downregulation of the AKT and MMP­2 pathways.


Asunto(s)
Movimiento Celular/efectos de los fármacos , Flavanonas/farmacología , Metaloproteinasa 2 de la Matriz/metabolismo , Proteínas Proto-Oncogénicas c-akt/metabolismo , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Relación Dosis-Respuesta a Droga , Regulación hacia Abajo , Humanos , Metaloproteinasa 2 de la Matriz/genética , FN-kappa B/genética , FN-kappa B/metabolismo , Proteínas Proto-Oncogénicas c-akt/genética , Transducción de Señal , Neoplasias de la Vejiga Urinaria/metabolismo
14.
J Chin Med Assoc ; 70(11): 511-3, 2007 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-18063507

RESUMEN

Intra-abdominal retained surgical sponge is an uncommon surgical error. Herein, we report a 92-year-old woman who was brought to the emergency room for acute urinary retention. She had a history of vaginal hysterectomy for uterine prolapse 18 years previously, performed at our hospital. Retained surgical sponge in the pelvic cavity was suspected by abdominal computed tomography. The surgical gauze was removed by laparotomy excision and the final diagnosis was gossypiboma.


Asunto(s)
Cuerpos Extraños/etiología , Tapones Quirúrgicos de Gaza/efectos adversos , Anciano , Anciano de 80 o más Años , Femenino , Cuerpos Extraños/diagnóstico , Humanos , Errores Médicos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...